Aeg F55200VI0 Bedienungsanleitung Seite 18

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 20
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 17
The quantity of detergent is too much.
Stains and dry water drops on glasses
and dishes
The released quantity of rinse aid is not
sufficient. Adjust the rinse aid selector
to a higher position.
The quality of the detergent can be the
cause.
Dishes are wet
The programme is without a drying
phase or with a low temperature drying
phase.
The rinse aid dispenser is empty.
The quality of the rinse aid can be the
cause.
The quality of the combi detergent tab-
lets can be the cause. Try a different
brand or activate the rinse aid dispens-
er and use rinse aid together with the
combi detergent tablets.
Refer to ‘HINTS AND TIPS’ for
other possible causes.
Activating the rinse aid
dispenser with the multitab
function activated
1. Press the on/off button to activate the
appliance.
2. Make sure that the appliance is in set-
ting mode. Refer to ‘SETTING AND
STARTING A PROGRAMME’.
3. Press and hold Delay and Start at the
same time until the indicators (A), (B)
and (C) flash.
4. Press Option .
The indicators (A) and (C) go off.
The indicator (B) continues to flash.
The display shows the setting of the
rinse aid dispenser.
Off
On
5. Press Option to change the setting.
6. Deactivate the appliance to confirm.
7. Adjust the released quantity of rinse
aid.
8. Fill the rinse aid dispenser.
TECHNICAL INFORMATION
Dimensions Width / Height / Depth (mm) 596 / 818 - 898 / 575
Electrical connection Refer to the rating plate.
Voltage 220-240 V
Frequency 50 Hz
Water supply pressure Min. / max. (bar / MPa) (0.5 / 0.05 ) / (8 / 0.8 )
Water supply
1)
Cold water or hot water
2)
max. 60 °C
Capacity Place settings 12
Power consumption Left-on mode 0.10 W
Off-mode 0.10 W
1)
Connect the water inlet hose to a water tap with a 3/4'' thread.
2)
If the hot water comes from alternative sources of energy, (e.g. solar panels, aeolian
energy), use the hot water supply to decrease energy consumption.
18