AEG HVB95450IB Bedienungsanleitung Seite 11

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 28
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 10
3.8 Replacement of the
connection cable
The replacement of electric
cable must be carried out
exclusively by the service
force centre or by personnel
with similar competencies, in
accordance with the current
regulations.
To replace the connection
cable use only H05SS-F T180
or equivalent type. Make
sure that the cable section is
applicable to the voltage
load and the working
temperature. The yellow/
green earth wire (B) must be
approximately 2 cm longer
than the live and neutral wire
(A).
A B
1. Connect the green and yellow (earth)
wire to the terminal which is marked
with the letter 'E', or the earth
symbol , or coloured green and
yellow.
2. Connect the blue (neutral) wire to the
terminal which is marked with the
letter 'N' or coloured blue.
3. Connect the brown (live) wire to the
terminal which is marked with the
letter 'L'. It must always be
connected to the network phase.
There must be no cut or stray strands
of wire present. The cord clamp must
be correctly attached to the outer
sheath.
3.9 Assembly
min.
100mm
min.
650mm
ENGLISH 11
Seitenansicht 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16 ... 27 28

Kommentare zu diesen Handbüchern

Keine Kommentare