Seitenansicht 13
Brown - Live
WARNING!
A cut off plug inserted into a
13 amp socket is a serious
shock hazard. Ensure that
the cut off plug is disposed
of safely.
8.5 Replacement of the
connection cable
The replacement of electric
cable must be carried out
exclusively by the service
force centre or by personnel
with similar competencies, in
accordance with the current
regulations.
To replace the connection
cable use only H05SS-F T180
or equivalent type. Make
sure that the cable section is
applicable to the voltage
load and the working
temperature. The yellow/
green earth wire (B) must be
approximately 2 cm longer
than the live and neutral wire
(A).
A B
1. Connect the green and yellow (earth)
wire to the terminal which is marked
with the letter 'E', or the earth
symbol
, or coloured green and
yellow.
2. Connect the blue (neutral) wire to the
terminal which is marked with the
letter 'N' or coloured blue.
3. Connect the brown (live) wire to the
terminal which is marked with the
letter 'L'. It must always be
connected to the network phase.
There must be no cut or stray strands
of wire present. The cord clamp must
be correctly attached to the outer
sheath.
8.6 Building In
min. 600 mm
min. 55 mm
min. 650 mm
560 mm
490 mm
min. 100 mm
30 mm
CAUTION!
Install the appliance only on
a worktop with flat surface.
8.7 Possibilities for insertion
The panel installed below the hob must
be easy to remove and let an easy access
in case a technical assistance
intervention is necessary.
www.aeg.com