AEG 69802 G Betriebsanleitung Seite 10

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 28
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 9
10
Burner Dia. Tap By-pass
1/100 mm
Auxiliary 28
Semi-rapid 32
Rapid 42
Aeration adjustment none
OVERALL DIMENSIONS Width: 580 mm.
Depth: 510 mm.
Height: 88 mm.
CUT OUT DIMENSIONS Width: 550 mm.
Depth: 470 mm.
Thickness: 30 mm.
SUPPLY CONNECTIONS Gas:
RC 1/2 inch (1/2 inch male) Rear right hand corner
Electric:
230 V 50 Hz supply, 3 core flexible cable with
non rewireable plug fitted with a 3 amp cartridge fuse.
HEAT INPUT
Rear Left Burner 1.9 kW (6483 BTU/HR)
(semi rapid)
Front Left Burner 2.9 kW Natural Gas (9895 BTU/HR)
(rapid) 2.7 kW L.P.G. (9212 BTU/HR)
Rear Right Burner 1.9 kW (6483 BTU/HR)
(semi rapid)
Front Right Burner 1.0 kW (3412 BTU/HR)
(auxiliary)
Instructions for the Installer
Engineer technical data
APPLIANCE CLASS 3
APPLIANCE
CATEGORY
II2H3+
GAS SUPPLY
Natural gas G20 / 20mbar
Instructions for the Installer