69802 GOperating Instructions Gas hobGBIE
10Burner Dia. Tap By-pass1/100 mmAuxiliary 28Semi-rapid 32Rapid 42Aeration adjustment noneOVERALL DIMENSIONS Width: 580 mm.Depth: 510 mm.Height: 88 mm
11BURNER RAPID SEMI-RAPID AUXILIARY(large) (medium) (small)POSITION MAX MIN MAX MIN MAX MIN NOMINAL THERMAL POWER kW 2.9 0.75 1.9 0.45 1
12LocationThe hob may be located in a kitchen, a kitchen/diner or bed sitting room, but not in abathroom or shower room.Before making the cut out in t
13InstallationIMPORTANTThis hob must be installed by a competent person to the relevant GasStandards.Any gas installation must be carried out by a reg
14It is important to install the elbow correctly, with the shoulder on the end of thethread, fitted to the hob connecting pipe.Failure to ensure the c
15550470580510Cut Out SizeThe dimensions of the cut-out are given in the diagram.Building InBuilding over a cupboard ordrawerIf the hob is to be insta
16Building over a kitchen unit with doorProper arrangements must be taken indesigning the furniture unit, in order toavoid any contact with the bottom
17Electrical connectionsAny electrical work required to install this hob should be carried out by a qualifiedelectrician or competent person, in accor
18Wiring diagram1. TAPS IGNITOR SWITCHES2. IGNITOR UNIT3. LED POWER INDICATORSPermanent ConnectionIn the case of a permanent connection, it is necessa
19Fault FindingPreliminary Electrical Systems CheckSTARTIsolate applianceand carry out:A: Earth Continuitycheck. Has inlet fuse blown?Carry out:C: Pol
2Important Safety InformationYou MUST read these warnings carefully before installing or using thehob. If you need assistance, contact our Customer Ca
20A. EARTH CONTINUITY CHECKAppliance must be electrically disconnected - meter set on Ω (Ohms) x 1 scale andadjust zero if necessary.— Test leads fro
21Check gas supply atburnerIgnition System / Gas IgnitionYESCheck plug top fuse andreplace if necessaryCheck polarity and earthcontinuity of supply po
22CommissioningWhen the hob has been fully installed it will be necessary to check the minimum flamesetting. To do this, follow the procedure below.1)
23Conversion from Natural Gas to LPGIMPORTANTThe replacement/conversion of the gas hob should only be undertaken by a competentperson.It is important
24Guarantee ConditionsStandard guarantee conditionsWe, AEG-Electrolux, undertake that if within 12 months of the date of the purchase this AEG-Electro
25Service and Spare PartsBefore calling out an engineer, please ensure you have read the details under the heading“Something not working”When you cont
26European GuaranteeThis appliance is guaranteed by Electrolux in each of the countries listed at the back of thisuser manual, for the period specifie
27
35686-0004 10/06Grafiche MDM - Forlìwww.aeg-electrolux.co.uk
3it has been installed. Ensure there is a continuous air supply, keeping air vents ingood condition or installing a cooker hood with a venting hose.!
4ContentsImportant Safety Information ... 2Instructions for the User ...
51. Hob Top2. Rapid Burner3. Semi-rapid Burners4. Auxiliary Burner5. Control knob for back right burner (semi-rapid)6. Control knob for back left burn
6Burner minimum maximumdiameter diameterLarge (rapid) 160 mm. 260 mm.Medium (semi-rapid) 120 mm. 220 mm.Small (Auxiliary) 80 mm. 160 mm.OperationAs so
7Fig. 2Fig. 1YESNOFig. 2Maintenance and CleaningBefore any maintenance or cleaning can be carried out, you must DISCONNECT thehob from the electricity
8The BurnersThe burner caps and crowns can be removed for cleaning. Wash the burner caps andcrowns using hot soapy water, and remove marks with a mild
9Something Not Working?If the hob is not working correctly, please carry out the following checks beforecontacting your local Service Force Centre.