Aeg HG654440SM Bedienungsanleitung Seite 26

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 64
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 25
8. INSTALLATION
WARNING!
Refer to the Safety chapters.
WARNING!
The following instructions about
installation, connection and
maintenance must be carried out
by qualified personnel in compli-
ance with standards and local
regulations in force.
8.1 Gas Connection
It is necessary that the connection to the
gas mains are carried out by means of an
AGB tap. Choose fixed connections or
use a flexible pipe in AGB (stainless
steel) in compliance with the regulation
in force. If you use flexible metallic
pipes, be careful they do not come in
touch with mobile parts or they are not
squeezed. Also be careful when the hob
is put together with an oven.
The connection must be done according
to regulation NBN D 5I.003.
Make sure that the gas supply
pressure of the appliance obeys
the recommended values. The
adjustable connection is fixed to
the comprehensive ramp by
means of a threaded nut G 1/2".
All the components shown in the
figure have already been assem-
bled in the factory. The appli-
ance, before leaving the factory,
has been tested in order to give
you the best results.
ABC
A)
End of shaft with nut
B)
Washer
C)
Elbow
Flexible nonmetal pipes
connection:
If it is possible to easily control the con-
nection in its full area, you can use a flex-
ible pipe. Tightly attach the flexible pipe
by clamps.
Liquid gas: use the rubber pipe holder.
Always engage the gasket. Then contin-
ue with the gas connection. The flexible
pipe is prepared for apply when:
it can not get hot more than room
temperature, higher than 30°C;
it is no longer than 1500 mm;
it shows no throttles;
it is not subject to traction or torsion;
it does not get in touch with cutting
edges or corners;
it can be easily examined in order to
check its condition.
The control of preservation of the flexi-
ble pipe consists in checking that:
it does not show cracks, cuts, marks of
burnings on the two ends and on its
full length;
the material is not hardened, but
shows its correct elasticity;
the fastening clamps are not rusted;
expired term is not due.
If one or more defects are visible, do not
repair the pipe, but replace it.
When installation is complete,
make sure that the seal of each
pipe fitting is correct. Use a
soapy solution, not a flame!
8.2 Injectors replacement
1.
Remove the pan supports.
2.
Remove the caps and crowns of the
burner.
3.
With a socket spanner 7 remove the
injectors and replace them with the
ones which are necessary for the
type of gas you use (see table in
"Technical Information" chapter).
4.
Assemble the parts, follow the same
procedure backwards.
5.
Replace the rating plate (it is near
the gas supply pipe) with the one for
the new type of gas supply. You can
26
www.aeg.com
Seitenansicht 25
1 2 ... 21 22 23 24 25 26 27 28 29 30 31 ... 63 64

Kommentare zu diesen Handbüchern

Keine Kommentare