WARNING!
Only liquid sealants can be
used when the inlet gas pipe
is fitted i.e.: do not use the
P.T.F.E. sealant tape.
When the installation is
complete, carry out a gas
tightness test and make sure
that the seal of each pipe
fitting does not leak.
Use flexible tubing, which
comply with the BS.669
current edition.
WARNING!
The gas bayonet connector
must be in the marked area.
Dimension mm
A 250
B 680
C 50
D 250
E 580
13.7 Pressure test
The Rapid injector is used as a pressure
test point.
1. Connect the pressure gauge to the
Rapid injector.
2. Examine the supply pressure by
turning the Rapid burner and one
other burner fully on, and lighting
them. The pressure must be 20 mbar
for Natural Gas.
3. Turn the taps off and disconnect the
pressure gauge.
4. Make sure that all burners work
correctly.
13.8 Checking the hob burners
1. Lift the lid.
2. Put on the burner crowns and caps.
Make sure that they are correctly
seated.
3. Put on the pan supports.
4. Light one of the hob burners.
To light the hob burner refer to the
"Ignition of the hob burners".
Check if the flame is regular.
Check each of the burners.
5. Turn the knob for the hob to the off
position.
13.9 Checking the Lid Safety
Device
1. Lift the lid.
2. Light one of the hob burners.
To light the hob burner refer to the
"Ignition of the hob burners".
3. Close the lid. There should be no gas
supply to the hob burners. The
burner goes out.
4. Turn the knob to the off position and
lift the lid. The gas supply should be
restored to the hob burners, when
you turn the knob on.
13.10 Electrical installation
WARNING!
The manufacturer is not
responsible if you do not
follow the safety precautions
from Safety chapters.
This appliance is supplied without a main
plug or a main cable.
www.aeg.com