of clamps fixed to the side of the
cabinet, in order to avoid any contact
with the equipment beneath the
cooktop.
Electrical Requirements
Permanent electrical installation must
agree with the latest I.E.E. Regulations
and local Electricity Board regulations.
For your own safety the installation must
be done by a qualified electrician (e.g.
your local Electricity Board, or a
contractor who is on the roll of the
National Inspection Council for Electrical
Installation Contracting [NICEIC]).
The manufacturer refuses
to be held responsible, if
these safety measures are
not abided by.
Supply connections
This hob has to be connected to 230 —
240 V ( 50 Hz) electricity supply.
The hob has a terminal block which is
marked as follows:
L or 1 - live terminal
N or 4 - neutral terminal
or E or 5 - earth terminal
Before carrying out the connection,
make sure:
1. The limiter valve and the electrical
system can take the appliance load
(see the rating plate)
2. The supply system is equipped with
an efficient earth connection in
compliance with the current
standards and regulations
3. The outlet or omnipolar switch used
for connection is easily accessible
with the appliance installed.
You must purchase and install the power
cable. Use only a connection cable of
type H05V2V2-F T90 or its equivalent.
Make sure that the cable section is
applicable to the voltage load and the
working temperature.
The wires in the cord are coloured as
follows:
Green and yellow - Earth
Blue - Neutral
Brown - Live
WARNING!
A cut off plug inserted into a
13 amp socket is a serious
shock hazard. Ensure that
the cut off plug is disposed
of safely.
8.8 Replacement of the
connection cable
The replacement of electric
cable must be carried out
exclusively by the service
force centre or by personnel
with similar competencies, in
accordance with the current
regulations.
Make sure that the cable
section is applicable to the
voltage load and the
working temperature. The
yellow/green earth wire (B)
must be approximately 2 cm
longer than the live and
neutral wire (A).
A B
1. Connect the green and yellow (earth)
wire to the terminal which is marked
with the number 5, or the letter 'E', or
the earth symbol
, or coloured
green and yellow.
2. Connect the blue (neutral) wire to the
terminal which is marked with the
number 4, or the letter 'N', or
coloured blue.
3. Connect the brown (live) wire to the
terminal which is marked with the
number 1, or the letter 'L'. It must
always be connected to the network