
9.6 Gas burners for LPG G30/G31 28-30/37 mbar
BURNER NORMAL
POWER kW
MINIMUM
POWER kW
INJECTOR
MARK 1/100
mm
NOMINAL GAS FLOW g/h
G30 28-30
mbar
G31 37 mbar
Rapid 2,7 0,75 86 196 193
Semi-rapid 1,9 0,45 71 138 136
10. ENERGY EFFICIENCY
10.1 Product information according to EU 66/2014
Model identification HD634170NB
Type of hob Built-in hob
Number of electric cooking zones 2
Heating technology per electric
cooking zone
Induction
Diameter of circular electric cooking
zones (Ø)
Left rear 14.0 cm
Left front 21.0 cm
Energy consumption per cooking
zone (ECelectric cooking)
Left front 183.7 Wh / kg
Left front 183.7 Wh / kg
Number of gas burners 2
Energy efficiency per gas burner
(EE gas burner)
Right rear - Rapid 61.3%
Right front - Semi-rapid 57.9%
Energy efficiency for the gas hob
(EE gas hob)
59.6%
Energy consumption of the hob (EC-
electric hob)
186.2 Wh / kg
EN 30-2-1: Domestic cooking appliances burning gas - Part 2-1 : Rational use of
energy - General
EN 60350-2 - Household electric cooking appliances - Part 2: Hobs - Methods for
measuring performance
10.2 Energy saving
• Before use, make sure that the burners and pan supports are assembled correctly.
• Use cookware with diameters applicable to the size of burners.
• Center the pot on the burner.
• When you heat up water, use only the amount you need.
• If it is possible, always put the lids on the cookware.
• When the liquid starts to boil, turn down the flame to barely simmer the liquid.
• If it is possible, use a pressure cooker. Refer to its user manual.
ENGLISH
25
Kommentare zu diesen Handbüchern