AEG 68001K Wartungshandbuch Seite 20

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 48
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 19
15 599 519 523 EN
DGS-TDS
21.04.08
3 Testing Power Component
1. When alarm messages and disabled zones exist ("E“ in cooking phase display), please make
a note of the power component which is affected.
2. (7) Check whether the lead from the filter board is connected, also check the bus lines (6)
µprocessors filter to power component.
3. If (8) IGBT has become shorted, this normally means that the IGBT housing is damaged.
Replace power component
4. (8) Measure resistance at the IGBTs
Pin1-Pin2 or Pin2-Pin3 >50kOhm Æ Okay
<50Ohm Æ power component defect & replace
Only replace the affected power component and (9) insert 20A fuse, completely separate the
fuse strip conductor.
S12 = right power component
S11 = left power component
5. By a short-circuit and destroyed power component, it is imperative that the coil lines be
inspected for signs of damage.
6. Also replace the filterboard should the replacement of the power component not succeed.
(6)
(6)
(7)
(7)
(8) 8 St. IGBT
Pin 1 2 3
(9)
Seitenansicht 19
1 2 ... 15 16 17 18 19 20 21 22 23 24 25 ... 47 48

Kommentare zu diesen Handbüchern