1. Operating Instructions
RTi 600 M HF
The RTi 600 M HF room temperature regulator is a mechanical two-position controller. When the
room temperature is too low, the fans of the storage heater in the RTi 600 M HF are switched on
automatically and operated at constant speed.
On reaching the room temperature set on the room temperature regulator, the fans are switched
off automatically by the RTi 600 M HF.
1.1 Functional Principle
The capillary tube thermostat measures the room temperature and switches the fan ON or OFF
accordingly. The desired room temperature can be set continuously with the selector knob on the
control panel.
If the selector knob is in the middle position, the room temperature is controlled constantly to
approx. 20 °C. By turning the selector knob to the left or right, the room temperature can be set
between about 7 °C and 30 °C.
When the room temperature drops below the set value, the room temperature regulator
automatically switches on the storage heater fan motors so that the stored heat is blown into the
room.
On very cold days it is advisable to leave the room temperature regulator switched on during long
periods of absence (several days) to keep the temperature at about 10 °C for example so that the
building or room does not go cold (protection against frost).
A day-acting element (supplied as an accessory) in the storage heater can be switched by means of
the illuminated rocker switch. The switch lights up when the DAE is in operation.
A night-time set back of ca. 3K can be achieved by a control current on terminal TA, for instance
by a manual switch, time-clock or central control